Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Orthopaedic Trauma ; (12): 876-880, 2020.
Article in Chinese | WPRIM | ID: wpr-867952

ABSTRACT

Objective:To explore the role of virtual reduction and design of 3D printed guide template in assisting reduction and internal fixation of comminuted patellar fractures.Methods:A retrospective study was conducted of 12 patients who had been treated for closed patellar fractures from March 2016 to April 2019 at Department of Orthopaedics, Jiangxi Provincial People's Hospital. They were 8 males and 4 females with an average age of 35.4 years (from 22 to 51). All their fractures were type 34-C3 (more than 3 fragments) according to the AO/OTA classification. Their preoperative CT data were imported into software Mimics to print a full patella, upper and lower halves of the patella, and a guide template for reduction. During operation, bone fragments were first temporarily fixated with a fine Kirschner wire after combined together with the assistance of reduction templates for upper and lower hemi-patellas. Next, the whole patella was precisely reset and definitely fixated using patellar ring ligation and tension band wire with the assistance of the reduction guide template for full patellar. Recorded were operation time, fluoroscopic frequency, and visual analogue scale (VAS), knee range of motion (ROM) and knee function B?stman scores at the last follow-up.Results:In this group of patients, operation time averaged 90 minutes (from 75 to 120 minutes), fluoroscopic frequency 4.5 times (from 3 to 8 times), follow-up duration 19 weeks (from 16 to 22 weeks), and fracture healing time 14 weeks (from 11 to 17 weeks). At their last follow-up, X-ray showed good patellar morphology, fine internal fixation positions and an average VAS pain scores of 0.3 (from 0 to 1), their knee joints could be fully straightened, their knee ROM averaged 130°(from 100° to 138°), and their knee B?stman scores 28.8 points (from 21 to 30 points), giving 9 excellent and 3 good cases.Conclusion:3D printed reduction guide templates can significantly improve the efficiency and quality of surgical reduction in comminuted patella fractures, enhancing fixation strength and facilitating early and full range exercise of the knee joint to achieve excellent recovery.

2.
Chinese Journal of Tissue Engineering Research ; (53): 7527-7533, 2013.
Article in Chinese | WPRIM | ID: wpr-437403

ABSTRACT

BACKGROUND:The treatment of severe rigid idiopathic scoliosis is the difficulty of clinical treatment. The studies in recent years have shown that the three-stage correction is a safe and effective treatment method. OBJECTIVE:To explore the efficacy of three-stage correction in the treatment of severe rigid scoliosis. METHODS:Retrospective analysis was performed on 10 severe rigid scoliosis patients undergoing three-stage correction, the mean age of the patients was 12 years. The average Cobb angle in the coronal plane was 140° (ranged 110°-180°), the average Cobb angle in the sagittal plane was 75° (ranged 50°-100°). The treatment was divided three stages:anterior release, Halo-plevic traction and third step with posterior osteotomy and fixation. RESULTS AND CONCLUSION:Al of the patients underwent the surgery safely without severe complications. After anterior release and Halo-plevic traction, the Cobb angle in the coronal plane was 90°, and the mean correction rate was 35.7%;the Cobb angle in the sagittal plane was 50° with correction rate of 33.3%. The mean Cobb angle in the coronal plane was 40° with the correction rate of 71.4%after osteotomy, and the Cobb angle in the sagittal plane was 35° with the correction rate of 53.3%. The results show that three-stage correction is a safe and effective method for the treatment of severe rigid scoliosis.

SELECTION OF CITATIONS
SEARCH DETAIL